SolarCity and Tesla solar owners

My SolarCity system shows an error. What now?

SolarCity became part of Tesla in 2016, but the inverter on your wall may be one of several brands. The brand decides what the error means.

Have my system diagnosed → System not producing? Start here

$219 · 20–45 minutes with David · fee may be applied toward a battery or new system

The short answer

SolarCity systems are now supported by Tesla, and monitoring moved to the Tesla app. SolarCity installed several inverter brands over the years, commonly SolarEdge and Delta, plus ABB/Power-One on some systems; newer Tesla installs use the Tesla Solar Inverter. Read the brand on the inverter’s label first. Ground or isolation faults and arc faults need a qualified technician. If you lease or pay a PPA, Tesla owns the equipment and handles the repair.

01

Lease or PPA

Tesla owns the system and handles repairs. Start with Tesla support in the Tesla app.

02

Bought it?

You own it. Equipment warranties may cover parts; check what still applies to a system this age.

03

Find the brand

Check the label on the inverter. SolarEdge and Tesla have their own guides here.

Safety first

Smoke, sparks, a burning smell or a hot panel

Stay clear, and call 911 if anything is burning. Do not open the inverter, unplug connectors or climb on the roof.

What you can safely do

Read the code, take a photo of the screen or app, and note when it started and the weather. Restart only the way the owner’s manual describes, and only once.

When to stop

If the same fault comes back, it is telling you something is wrong. Repeated resets can hide a real wiring or insulation problem.

By inverter brand

SolarEdge

Isolation faults (ground leakage) and arc detection are the ones that matter. See our SolarEdge error guide.

ABB / Power-One: “Riso Low”

Before connecting each morning, the inverter tests the panels’ insulation to ground and won’t start below its limit (1 MΩ in the manual). Owners often see it only on damp mornings, clearing by midday: that pattern usually points to a wet connector, junction box or damaged cable on the roof, not the inverter. A reading stuck at 0.00 more often means the inverter itself.

ABB / Power-One: E018, E031, W003

E018 is a leakage-current fault on the DC side. E031 is an output-relay fault inside the inverter, a common failure on older units. W003 is a grid warning: utility voltage or frequency was outside the allowed range, which often clears on its own.

Delta: red “Earth Fault” light, errors 506 / 508

The red Earth Fault light and errors 506 (while running) or 508 (at start-up) mean an insulation or grounding fault on the panel side, usually worn cable, water in a connector or a damaged panel. Some Delta units keep producing and only warn, so a fault can sit unnoticed for months.

Before anyone replaces an inverter

An insulation test with a megohmmeter, string by string, tells a roof fault from an inverter fault. Replacing the inverter won’t fix a wet connector.

Tesla Solar Inverter

An isolation alert points to a wiring fault on a string. Repeated arc faults can lock the inverter out until an installer inspects it. “Service Required – Fault Detected” in the app means an inverter may have stopped producing: contact Tesla or your installer.

If the Tesla app shows nothing

Check the inverter first

If the inverter screen shows power but the app has no data, the system may be producing fine and only the monitoring connection is down.

Night is normal

Many inverters go dark or sleep after sunset. Check again in midday sun.

Use your bill

Your utility bill shows what you sent to the grid. A sudden drop is the clearest sign production fell.

General information from Your Energy Best; your account and agreement control. Last reviewed November 23, 2026. Sources: Tesla: system alerts Tesla: solar inverter troubleshooting Tesla: arc fault lockout pv-tech: Tesla to use its own inverters for SolarCity Power-One Aurora PVI-3.0/4.2 manual Delta Solivia manual: LEDs and faults DIY Solar Forum: ABB low Riso in the mornings

Where we work

What's different depends on your utility. Find your city:

San Diego Community Power (SDCP)

San Diego · Encinitas · Ramona

Fixing a system anyway? It's a good moment to see whether a battery would qualify for SDCP's rebate.

  • Encinitas: The coastal marine layer can delay morning production, so we size for it.
  • Ramona: Real fire risk and outage history: backup power often matters more than savings here.

Clean Energy Alliance (CEA)

Carlsbad · Oceanside · Vista · San Marcos · Solana Beach · Del Mar · Escondido

Repairing or replacing equipment? CEA Solar Plus can add a battery at the same time, $0 down.

  • Oceanside: Lots of older homes: we check the main electrical panel up front.
  • Del Mar: Salt air: we check mounting and wiring for corrosion.
  • Escondido: Hot inland summers: air conditioning shapes system and battery sizing.

SDG&E in South Orange County

San Clemente · Dana Point · San Juan Capistrano

Coastal salt air is a common cause of corroded connectors and failing inverters; we check for it first.

Southern California Edison (SCE)

Long Beach · The rest of Orange County

Same troubleshooting on Edison systems, wherever your installer was based.

Straight answers

What should I watch in my monitoring app — and when should I worry?

Your app (Enphase, Tesla, SolarEdge, or your PPA provider's) shows production and, with a battery, storage behavior. The one metric that matters: production versus the same period last year. Weather varies, seasons swing — but if production drops significantly in a short window or year-over-year with similar weather, a panel or inverter likely needs service. That's genuinely the only failure mode solar-only systems really have.

Battery acting weird? Check the mode first — standby/backup (saves for emergencies), self-consumption (drains nightly), and time-of-use (follows rate schedules) behave completely differently, and a mode switch is the #1 "my battery is broken" false alarm. Not charging fully or dumping too fast on the right mode? Something's pulling more power than it can serve, or it needs service. Then you call — and if your installer is gone, that's what I'm here for.

Read this answer on its own page →
What is a Solar Health Audit — and do I need one?

An audit answers the question most solar owners can't: "Is this thing actually working for me?" Six data points tell the whole story: year-over-year consumption, year-over-year production, install date, current utility rates, your solar payment, and any true-up costs.

From those, the math falls out: yearly consumption × current utility rate = what you'd pay without solar. Subtract your annualized solar payments and true-ups = your real savings. Compare production to consumption = whether you're over- or under-producing, and whether usage changes (new EV? teenager with a gaming rig?) have outgrown your design. My audit also reviews your agreement terms against what's fair and flags rebates you're leaving unclaimed — SDCP funds, VPP enrollment, the works. If you've had solar 2+ years and never checked, you're overdue.

Request your audit →
Read this answer on its own page →
How much maintenance does solar actually need?

Shockingly little — this is one place the sales guys undersell. Panels have no moving parts and run 25-30+ years. The honest maintenance list: watch your monitoring app (5 minutes a month), clean the panels once a year in low-rain areas like ours (before summer, after pollen season — de-ionized water and regular soap, never when panels are hot, or just hire a cleaner), and a system health check every 5-10 years.

The components that can actually need service over decades: inverters (that's why warranty length matters — 12.5 vs 25 years is a real difference) and batteries (10-15 year warranties). The panels themselves? They'll likely outlive your roof.

Read this answer on its own page →
I got a surprise true-up bill. What happened?

The true-up is your annual settle-up with the utility for energy your system didn't cover. Surprise bills almost always trace to one cause: your usage grew past your design. New EV, hot tub, home office, kids getting older, more AC in a hotter summer — the system was sized for the life you had, not the life you have.

Sometimes it's the design's fault (sized to a single bill instead of real usage data), and occasionally it's underproduction from a failed component. An audit separates the causes in about an hour: production data tells us if the system is healthy; consumption data tells us if your life outgrew it. The fix ranges from mode changes and habit shifts (free) to added panels or battery (an investment that beats paying the utility forever). What you shouldn't do is just quietly pay it every year.

Read this answer on its own page →

More in the Knowledge Center →

Ready when you are.

Have my system diagnosed →